ShieldSpecification

Note: There is a newer version of this specification see VEC 2.1.0

Specifies the properties of a shield.

General Information

Attribute Value
Owner electrical_parts
Applied Stereotype
Base Classifier ConductorSpecification
Is Abstract false
Derived Classifiers

Attributes

Name Type Mult. Description Owning Classifier
identification String 1

Specifies a unique identification of the specification. The identification is guaranteed to be unique within the document containing the specification. For all VEC-documents a Specification-instance can be trusted to be identical if the DocumentVersion-instance is the same (see DocumentVersion) and the identification of the Specification is the same.

Specification
description AbstractLocalizedString 0..*

Specifies additional, human readable information about the specification.

Specification
crossSectionArea NumericalValue 0..1

Specifies the cross-section area of the conductor (e.g. 0,5 mm²). The cross-section area is a nominal value, which refers to the conducting properties of the conductor normalized to the properties of a full material core.

ConductorSpecification
massInformation MassInformation 0..1

Specifies the mass information of the conductor. In most cases this mass information is known as copper weight and is normally specified as mass per length (e.g. gram per meter).

ConductorSpecification
material Material 0..*

Specifies the material of the conductor.

ConductorSpecification
resistance NumericalValue 0..1

Specifies the electrical resistance of the conductor. In most cases this is specified as resistance per length (e.g. Ohm per meter).

ConductorSpecification
structure ConductorStructure 0..1

Specifies the structure of the conductor according to ISO 6722-1 for ConductorSpecifications with Type = Stranded.

Should only be used for ConductorSpecifications with type=Stranded.

 

ConductorSpecification
type ConductorType 0..1

Specifies the type of the conductor, e.g. if it is rigid or stranded.

ConductorSpecification
numberOfStrands NumericalValue 0..1

Specifies the number of strands in one conductor. If the conductor is solid than the number of strands would be one.

ConductorSpecification
platingMaterial Material 0..*

Specifies the plating material of the conductor.

ConductorSpecification
strandDiameter NumericalValue 0..1

Specifies the diameter of a single strand in the conductor.

ConductorSpecification
voltageRange NumericalValue 0..1

Specifies the voltageRange for which the conductor is approved.

ConductorSpecification
opticalTissueDensity NumericalValue 0..1

Defines the optical tissue density of the strands of a shield. This is defined as a value in percentage.

Should only be used for ShieldSpecifications with type=Braided.

 

ShieldSpecification
windingType FoilShieldWindingType 0..1

Defines the type of winding of the shield.

Should only be used for ShieldSpecifications with type=Foil.

ShieldSpecification
Previous