TerminalCurrentInformation
Note: There is a newer version of this specification see VEC 2.1.0
Allows the definition of valid current ranges for a terminal. A current range is always defined for a coreCrossSectionArea and a nominal voltage. Attributes of the type CurrentRangeInformation normally have the multiplicity [0..*]. This means that such an attribute can have CurrentRangeInformation entries for different coreCrossSectionAreas and nominalVoltages. It must not have multiple entries for the same coreCrossSectionAreas and nominalVoltages.
General Information
Attribute | Value |
---|---|
Owner | electrical_parts |
Applied Stereotype | |
Base Classifier | |
Is Abstract | false |
Derived Classifiers |
Attributes
Name | Type | Mult. | Description | Owning Classifier |
---|---|---|---|---|
currentRange | ValueRange | 1 | Specifies the valid current range for the terminal. It is defined as a value range, because there are terminals where minimum current is needed to avoid corrosion. |
TerminalCurrentInformation |
nominalVoltage | NumericalValue | 1 | Specifies the nominalVoltage for which the CurrentRangeInformation is valid. |
TerminalCurrentInformation |
coreCrossSectionArea | NumericalValue | 1 | Specifies the coreCrossSectionArea for which the CurrentRangeInformation is valid. The coreCrossSectionArea is a relevant information, because the thermal absorption of the core depends on the cross-section area and thus is an influence factor for the valid current range. |
TerminalCurrentInformation |
Incoming Relations
This End | Other End | General | |||||
---|---|---|---|---|---|---|---|
Role | Mult. | Agg. | Unique | Ordered | Type | Mult. | Description |
currentInformation | 0..* | Y | Y | N | TerminalSpecification | 1 | Specifies the TerminalCurrentInformation that is applicable for the terminal. |