ConductorSpecification

Note: There is a newer version of this specification see VEC 2.1.0

Specification for the definition of conducting properties of a WireElement.

General Information

Attribute Value
Owner electrical_parts
Applied Stereotype
Base Classifier Specification
Is Abstract true
Derived Classifiers CoreSpecification, FlatCoreSpecification, ShieldSpecification

Attributes

Name Type Mult. Description Owning Classifier
identification String 1

Specifies a unique identification of the specification. The identification is guaranteed to be unique within the document containing the specification. For all VEC-documents a Specification-instance can be trusted to be identical if the DocumentVersion-instance is the same (see DocumentVersion) and the identification of the Specification is the same.

Specification
description AbstractLocalizedString 0..*

Specifies additional, human readable information about the specification.

Specification
crossSectionArea NumericalValue 0..1

Specifies the cross-section area of the conductor (e.g. 0,5 mm²). The cross-section area is a nominal value, which refers to the conducting properties of the conductor normalized to the properties of a full material core.

ConductorSpecification
massInformation MassInformation 0..1

Specifies the mass information of the conductor. In most cases this mass information is known as copper weight and is normally specified as mass per length (e.g. gram per meter).

ConductorSpecification
material Material 0..*

Specifies the material of the conductor.

ConductorSpecification
resistance NumericalValue 0..1

Specifies the electrical resistance of the conductor. In most cases this is specified as resistance per length (e.g. Ohm per meter).

ConductorSpecification
structure ConductorStructure 0..1

Specifies the structure of the conductor according to ISO 6722-1 for ConductorSpecifications with Type = Stranded.

Should only be used for ConductorSpecifications with type=Stranded.

 

ConductorSpecification
type ConductorType 0..1

Specifies the type of the conductor, e.g. if it is rigid or stranded.

ConductorSpecification
numberOfStrands NumericalValue 0..1

Specifies the number of strands in one conductor. If the conductor is solid than the number of strands would be one.

ConductorSpecification
platingMaterial Material 0..*

Specifies the plating material of the conductor.

ConductorSpecification
strandDiameter NumericalValue 0..1

Specifies the diameter of a single strand in the conductor.

ConductorSpecification
voltageRange NumericalValue 0..1

Specifies the voltageRange for which the conductor is approved.

ConductorSpecification

Outgoing Relations

Other End This End General
Role Type Mult. Agg. Unique Ordered Mult. Description
currentInformation ConductorCurrentInformation 0..* Y Y N 1

Specifies the current information of the conductor. These are the maximum currents for which the conductor is approved.

Incoming Relations

This End Other End General
Role Mult. Agg. Unique Ordered Type Mult. Description
conductorSpecification 0..1 N Y N WireElementSpecification 0..*

If the WireElement has a core then the specification of the core is referenced here.

conductorSpecification 0..1 N Y N InternalComponentConnection 0..*
recommendedConductorSpecification 0..1 N Y N Signal

Defines a recommended Specification for the cores that implement this signal.

referencedCoreSpecification 1 N Y N TerminalPairing 0..*

References the CoreSpecification that is used on both sides of the ContactSystem.

Previous