A contact point defines the relationship between Terminals, Seals, Plugs, Cavities and Wires. It specifies a single contacting variant. This means that the contacting is manufactured, as specified by the ContactPoint. Either all participants (Cavities, Terminals, Seals, Wires) set into a relationship by the ContactPoint exist in a specific harness or none. There is no requirement, to filter the participants of a contacting situation with information derived from VariantConfigurations or assembly / module associations in order to create a manufacturing variant.
The ContactPoint represents a single potential. Consequently, all cavities and wires referencing / being referenced by a ContactPoint are short-circuited and have the same potential (even if the signals on the wires are named differently. If a contacting of a terminal has more than one potential (e.g. a coax-contact) one contact point for each potential is needed.
Attribute |
Value |
Owner |
contacting |
Applied Stereotype |
|
Base Classifier |
ConfigurableElement
|
Is Abstract |
false |
Derived Classifiers |
|
Attributes
Name |
Type |
Mult. |
Description |
Owning Classifier |
identification |
String |
0..1 |
Specifies a unique identification of the ContactPoint. The identification is guaranteed to be unique within the ContactingSpecification. |
ContactPoint |
Outgoing Relations
Other End |
This End |
General |
Role |
Type |
Mult. |
Agg. |
Unique |
Ordered |
Mult. |
Description |
wireMounting |
WireMounting |
0..* |
Y |
Y |
N |
1 |
Specifies the WireMouting defined by ContactPoint. More than one WireMounting is allowed in order to support variance. In concrete configuration the WireMounting with all referenced elements present is used. |
mountedTerminal |
TerminalRole |
0..1 |
N |
Y |
N |
0..* |
References the terminal that is used for contacting defined by the ContactPoint. |
cavityMounting |
CavityMounting |
0..* |
Y |
Y |
N |
1 |
Defines the mounting to a cavity of the terminal associated with the ContactPoint. The cardinality is 0..* in order to allow a variant dependant cavity mounting. In such a scenario a cavity mounting is valid in a configuration if all addressed cavities and therefore the associated connector housing is available. |
Incoming Relations
This End |
Other End |
General |
Role |
Mult. |
Agg. |
Unique |
Ordered |
Type |
Mult. |
Description |
contactPoint |
0..* |
Y |
Y |
N |
ContactingSpecification |
1 |
Specifies the ContactPoints defined by the ContactingSpecification. |
contactPoint |
1 |
N |
Y |
N |
PinWireMappingPoint |
|
|