InsulationCrimpDetail

The InsulationCrimpDetail defines crimp values for a insulation crimp. The selection criteria to which the InsulationCrimpDetail applies are defined by the referenced InsulationSpecification and the ConductorSpecification referenced by the containing CoreCrimpDetail.

General Information

Attribute Value
Owner electrical_parts
Applied Stereotype
Base Classifier CrimpDetail
Is Abstract false
Derived Classifiers

Attributes

Name Type Mult. Description Owning Classifier
size Size 0..1

Defines the expected size of the crimp. The height is measured in direction of the crimp opening. The width is measured in orthogonal to the height and orthogonal to main axis of the terminal (TerminalSpecification.OverallLength).

CrimpDetail
pullOffForce NumericalValue 0..1

The minimum force that the completed crimp should withstand when wire is being pulled off the terminal. Above that force, the crimp can be expected to be destroyed at any time.

InsulationCrimpDetail

Outgoing Relations

Other End This End General
Role Type Mult. Agg. Unique Ordered Mult. Description
appliesTo InsulationSpecification 1 N Y N

Incoming Relations

This End Other End General
Role Mult. Agg. Unique Ordered Type Mult. Description
insulationCrimpDetails 0..* Y Y N CoreCrimpDetail 1

Defines the different InsulationCrimpDetails that are valid combinations for this CoreCrimpDetail.

Previous