TerminalCurrentInformation

Allows the definition of valid current ranges for a terminal. A current range is always defined for a coreCrossSectionArea and a nominal voltage. Attributes of the type CurrentRangeInformation normally have the multiplicity [0..*]. This means that such an attribute can have CurrentRangeInformation entries for different coreCrossSectionAreas and nominalVoltages. It must not have multiple entries for the same coreCrossSectionAreas and nominalVoltages.

General Information

Attribute Value
Owner electrical_parts
Applied Stereotype
Base Classifier
Is Abstract false
Derived Classifiers

Attributes

Name Type Mult. Description Owning Classifier
currentRange ValueRange 1

Specifies the valid current range for the terminal. It is defined as a value range, because there are terminals where minimum current is needed to avoid corrosion.

TerminalCurrentInformation
nominalVoltage NumericalValue 1

Specifies the nominalVoltage for which the CurrentRangeInformation is valid.

TerminalCurrentInformation
coreCrossSectionArea NumericalValue 1

Specifies the coreCrossSectionArea for which the CurrentRangeInformation is valid. The coreCrossSectionArea is a relevant information, because the thermal absorption of the core depends on the cross-section area and thus is an influence factor for the valid current range.

TerminalCurrentInformation

Incoming Relations

This End Other End General
Role Mult. Agg. Unique Ordered Type Mult. Description
currentInformation 0..* Y Y N TerminalSpecification 1

Specifies the TerminalCurrentInformation that is applicable for the terminal.